El ensuciamiento de los MBR
- García Rodríguez, Ana 1
- Martínez Díaz, Raquel 1
- Ramos Rodríguez, Cipriano 1
- Díez Blanco, Victorino 1
-
1
Universidad de Burgos
info
- Sarabia Peinador, Luis Antonio (dir.)
- Iglesias Río, Miguel Ángel (coord.)
Éditorial: Servicio de Publicaciones e Imagen Institucional ; Universidad de Burgos
ISBN: 84-16283-16-8, 978-84-16283-18-7, 84-16283-18-4
Année de publication: 2015
Pages: 573-580
Congreso: Jornadas de Doctorandos de la Universidad de Burgos (2. 2015. Burgos)
Type: Communication dans un congrès
Résumé
Fouling in membrane bioreactors, MBR, it’s a critical point. Hydraulic resistance quantifies the degree of fouling and identified where it’s located. It was studied the influence of effluent concentration on fouling resistance measurement in different dilutions, 1:2 and 1:4, with deionized water, fouling alteration provoked by ex situ measurement method decreasing 40% respect to the resistance obtained in the reactor.
Los documentos del portal se actualizan diariamente. Esta fecha hace referencia a la actualización de la información relacionada con la estructura del portal (personas, grupos de investigación, unidades organizativas, proyectos...).